FiOS Phone - Determine if Your ONT has Power An Optical Network Terminal (ONT) is a small Verizon box generally located on the outside wall of your home. It has a power cord that goes into your home through your Battery Back-Up Unit (BBU)* where it plugs into an existing standard AC outlet.

Before performing the isolating procedure, you need to confirm that the ONT is receiving power. In the case of a power disruption, the BBU will provide power to the ONT. Follow the steps below to determine if the ONT has power. You will need a flat-head screwdriver to open the ONT, and we recommend taking a flashlight and a copy of these instructions with you, if possible.

Note Although the lines are grounded, do not attempt to open the ONT or test the lines during rain, a thunderstorm, or other hazardous weather conditions. If there is a loud hum on the line, do not test the ONT. Call the Verizon Fiber Solutions Center.
To determine if the ONT has power:
  1. Locate the ONT and remove the screw that holds the ONT cover closed.


  2. Open the cover and check the Power light.

If the Power light is:

  • Green
    The ONT has power.
    Complete the test procedure for an ONT to determine if the problem is with the inside or outside wiring.

  • Blinking
    The ONT is operating in Battery mode.
    A fully charged battery will power the voice ports on the ONT for up to eight hours during a power outage.

  • Dark
    The ONT has lost power.
    If the ONT is accidentally unplugged, or in the event of a commercial power failure, it is possible that the battery is not properly connected or is dead. If you have not yet checked the Battery Indicator light or battery connection, check the Battery Back-Up unit.
    If the Battery Indicator light on the BBU is still lit or your service is still not working, contact the Verizon Fiber Solutions Center.


You can make a request for repair online

FiOS Phone Service may not be available in all areas.

*Important Note The Verizon supplied battery is designed specifically for use with the Verizon FiOS Network. Use of a battery other than a 12-Volt 7.2 Ah SLA Sealed Lead Acid battery is not recommended since other battery types may impact the performance of your FiOS services. Verizon is not responsible for damages which result from use of an improper battery.


See also:Related FiOS Phone Service topics

My Preferences

Internet: High Speed Internet

TV: FiOS TV

Ask Verizon
Your automated customer service agent

Repair Status

To view, update or cancel your repair request enter your phone or data line number.

red arrowCheck with user name

Check Status

Order Status

View order progress, connection date and more

red arrow Check Order Status


About Us | Contact Us |  | Careers | Verizon Foundation | Site Map | Privacy Policy | Terms and Conditions | Site Feedback
© 2009 Verizon
TRUSTe Certified Privacy Better Business Bureau: Accredited Business