The purpose of this guide is to assist carriers with ordering FiberConnect Service
FiberConnect Service is an interstate Special Access product, which terminates 4 DS1 circuits at the Customers Designated Location (CDL), via a fiber facility. This product will target cellular customers who want their DS1 service on fiber facilities but will not be restricted for cellular customers only. The customer orders FiberConnect with an electrical interface and four transmission channels at 1.544 Mb/s. This product is currently available in the West.
Prior to submitting an ASR, carriers should use the Pre-Order Validation Tools in CSG. By using these functions, carriers will be able to validate fields on their ASRs prior to submission. All fields on the ASR must be populated according to the Access Business Rules
All orders for FiberConnect will require a Service Inquiry ASR before a firm order can be placed. The following guidelines describe the required fields for a Service Inquiry (including those not listed here) must be populated according to the Access Business Rules. The SPEC codes and NC/NCI combinations listed below are to be used for both a Service Inquiry and a Firm Order.
Field |
Description
|
---|---|
REQTYP | EA or SA |
ICSC | GT10,GT12 |
QSA | Equals the total number of SALI forms needed |
LSO | REQTYP "E" ONLY |
SECLOC | REQTYP "S" ONLY |
SECLOC LSO | REQTYP "S" ONLY |
ACTL | REQTYP "S" ONLY |
*In addition to the above BAU fields required on all Service Inquiries, the fields below are required on the Service Inquiry specifically for FiberConnect Service:
After receiving the Service Request Confirmation, the customer can submit a firm ASR. A complete ASR is essential to properly provision and bill FiberConnect access services. All fields on the ASR (including those not listed here) must be populated according to the Access Business Rules.
Field |
Description
|
---|---|
REQTYP | EC or SC |
ICSC | GT10,GT12 |
QSA | Equals the total number of SALI forms needed |
QTY | 4 |
PIU | 100 |
VTA | 12FO,36FO, 60FO OPP term |
NC/NCI Code | *please see charts below |
SECNCI Code | *please see charts below |
SPEC Code | *please see charts below |
Network Channel / Network Channel Indicator / Secondary Network Channel Indicator
The following are valid FiberConnect Combinations.
Type | NC | NCI | SECNCI |
---|---|---|---|
DS1 - ANSI, ESF, & AMI - point to point - Collocation to End User | HCD- | 04QB9.11 | 04DU9.1KN |
DS1 with DS3 Termination - ANSI, ESF, & AMI - point to point - Collocation to End User | 04QB6.33 | 04DU9.1KN | |
DS1 - ANSI, ESF, & AMI - point to point - Collocation to End User - HVP | 04QB9.11 | 04DU9.1KG | |
DS1 with DS3 Termination - ANSI, ESF, & AMI - point to point - Collocation to End User - HVP | 04QB6.33 | 04DU9.1KG | |
DS1 - ANSI, ESF, & AMI - point to point - End User to End User | 04DU9.1KN | 04DU9.1KN | |
DS1 - ANSI, ESF, & AMI - point to point - Access to End User | 04DS91K | 04DU9.1KN | |
DS1 with DS3 Termination - ANSI, ESF, & AMI - point to point - Access to End User | 04DS6.44 | 04DU9.1KN | |
DS1 - ANSI, ESF, & AMI - point to point - Access to End User - HVP | 04DS91K | 04DU9.1KG | |
DS1 with DS3 Termination - ANSI, ESF, & AMI - point to point - Access to End User - HVP | 04DS6.44 | 04DU9.1KG |
Type | NC | NCI | SECNCI |
---|---|---|---|
DS1 - SF/AMI, point to point, Collocation to End User | HC-- | 04QB9.11 | 04DU9.BN |
DS1 with DS3 Termination - SF/AMI, point to point, Collocation to End User | 04QB6.33 | 04DU9.BN | |
DS1 - SF/AMI, point to point, Collocation to End User - HVP | 04QB9.11 | 04DU9.BNG | |
DS1 with DS3 Termination - SF/AMI, point to point, Collocation to End User - HVP | 04QB9.15 | 04DU9.BNG | |
DS1 - SF/AMI, point to point, End User to End User | 04DU9.BN | 04DU9.BN | |
DS1 - SF, AMI, point to point. Access to End User | 04DS9.15 | 04DU9.BN | |
DS1 with DS3 Termination - SF, AMI, point to point, Access to End User | 04DS6.44 | 04DU9.BN | |
DS1 - SF, AMI, point to point. Access to End User - HVP | 04DS9.15 | 04DU9.BNG | |
DS1 with DS3 Termination - SF, AMI, point to point, Access to End User - HVP | 04DS6.44 | 04DU9.1SG |
Type | NC | NCI | SECNCI |
---|---|---|---|
DS1 - SF & B8ZS - point to point - Collocation to End User | HCZ- | 04QB9.11 | 04DU9.DN |
DS1 with DS3 Termination -SF & B8ZS - point to point - Collocation to End User | 04QB6.33 | 04DU9.DN | |
DS1 - SF & B8ZS - point to point - Collocation to End User - HVP | 04QB9.11 | 04DU9.DNG | |
DS1 with DS3 Termination -SF & B8ZS - point to point - Collocation to End User - HVP | 04QB6.33 | 04DU9.DNG | |
DS1 - SF & B8ZS - point to point - End User to End User | 04DU9.DN | 04DU9.DN | |
DS1 - SF & B8ZS - point to point - Access to End User | 04DS9.15B | 04DU9.DN | |
DS1 with DS3 Termination - SF & B8ZS - point to point - Access to End User | 04DS6.44 | 04DU9.DN | |
DS1 - SF & B8ZS - point to point - Access to End User - HVP | 04DS9.15B | 04DU9.DNG | |
DS1 with DS3 Termination - SF & B8ZS - point to point - Access to End User - HVP | 04DS6.44 | 04DU9.DNG |
Type | NC | NCI | SECNCI |
---|---|---|---|
DS1 - ANSI, ESF, & B8ZS - point to point - Collocation to End User | HCE- | 04QB9.11 | 04DU9.1SN |
DS1 with DS3 Termination - ANSI, ESF, & B8ZS - point to point - Collocation to End User | 04QB6.33 | 04DU9.1SN | |
DS1 - ANSI, ESF, & B8ZS - point to point - Collocation to End User - HVP | 04QB9.11 | 04DU9.1SG | |
DS1 with DS3 Termination - ANSI, ESF, & B8ZS - point to point - Collocation to End User - HVP | 04QB6.33 | 04DU9.1SG | |
DS1 - ANSI, ESF, & B8ZS - point to point - End User to End User | 04DU9.1SN | 04DU9.1SN | |
DS1 - ANSI, ESF, & B8ZS - point to point - Access to End User | 04DS9.15B | 04DU9.DN | |
DS1 with DS3 Termination - ANSI, ESF, & B8ZS - point to point - Access to End User | 04DS6.44 | 04DU9.1SN | |
DS1 - ANSI, ESF, & B8ZS - point to point - Access to End User - HVP | 04DS9.1S | 04DU9.1SG | |
DS1 with DS3 Termination - ANSI, ESF, & B8ZS - point to point - Access to End User - HVP | 04DS6.44 | 04DU9.1SG |
Service and Product Enhancement Code.
SPEC Code |
Description
|
---|---|
FOL1ZX | DS1 with FiberConnect at terminating end ONLY - Secondary location - SECLOC |
FOL1AX | DS1 with FiberConnect at originating end ONLY - Primary location - PRILOC |
FOL1AZ | DS1 with FiberConnect at originating and terminating end - Primary and Secondary locations - PRILOC and SECLOC |
Additional SPEC codes are for use where FiberConnect can be ordered with another service which has a SPEC code requirement.
SPEC Code |
Description
|
---|---|
FOLSPZX | MetroLan DS1 with FiberConnect at terminating end ONLY - Secondary location - SECLOC |
FOLSPAX | MetroLan DS1 with FiberConnect at originating end ONLY - Primary location - PRILOC |
FOLSPAZ | MetroLan DS1 with FiberConnect at originating and terminating end - Primary and Secondary location - PRILOC and SECLOC |
FOLDSZX | DSR DS1 Rider with FiberConnect at terminating end ONLY (SCFA must be DSR) - Secondary location - SECLOC |
FOLDSAX | DSR DS1 Rider with FiberConnect at originating end ONLY (DSR CFA must be present) - Primary location - PRILOC |
For more information about the VTA field, please see the VTA Job Aid.