The purpose of this document is to assist carriers with ordering IntelliLight Entrance Facility (IEF) service.
IntelliLight® Entrance Facility (IEF) service is an entrance transport alternative using a shared SONET ring which provides loop protection for a customer's DS1, DS3, STS1, OC3/OC3c and OC12/12c services.
When IEF is ordered, the standard Verizon network design is over a shared self-healing, SONET ring (except OC48 Mid-span meet) that passes through Verizon's wire centers and the customer's location. One of the wire centers must be the wire center of the customer's designated premises; the other wire center is selected by Verizon. When IEF access is provisioned over a high speed OC48 mid-span meet, the entire Bandwidth is committed to the customer. The customer's SONET facilities are spliced with Verizon's SONET facilities at a designated meet point referred to as the mid-span meet.
IEF is associated with a basic underlying service (e.g., DS1, DS3, OCn) and is a transport enhancement to that service.
> Read more about IntelliLight Entrance Facility (IEF) service.
All requests for IEF access require pre-negotiation by your planning organization and your Account Manager. Your Verizon Account Manager is responsible for providing pricing information, service availability, due dates, as well as coordinating with Verizon's Network personnel to provide schematics and check for facilities. IEF requires a SONET self-healing ring connecting two Verizon Wire Centers. It is important that your planner is specific in defining your physical entrance ring to Verizon.
After all pre-sale negotiation and pricing is complete you will be able to submit an ASR
When this product is ordered under a private carriage agreement (Forbearance), the Contract ID must be populated in the PNUM Field on the ASR Form. Learn more about Forbearance or contact your Account Manager for more details.
A complete ASR is essential to accurately provision and bill IEF access services. The IEF Order Sample provides an example of which fields should be entered for an IEF request. The Table below provides field details for a number of IEF variations (i.e., OCn's, DS1's on IEF Loops, etc.)
Field | Field Name | Description |
---|---|---|
ACTL | Access Customer Termination Location | Identifies the CLLI Code of the customer facility terminal location. |
BAN | Billing Account Number | The BAN you want the service billed. When "N" is entered in this field a new billing account will be assigned. |
NC | Network Channel | See NC / NCI / SEC NCI table below |
NCI | Network Channel Interface | See NC / NCI / SEC NCI table below |
PIU | Percent of Interstate Usage | 100 |
PNUM | Promotion Number | The Contract ID is required for new service in the PNUM field on the ASR Form (example - FB12345) |
REQTYP | Requisition Type and Status | SD |
SEC NCI | Secondary Network Channel Interface | See NC / NCI / SEC NCI table below |
SPEC | Service and Product Enhancement Code | See SPEC section below |
VTA | Variable Term Agreement | Available in 3 or 5 year terms: See VTA section below for more information |
Network Channel / Network Channel Indicator / Secondary Network Channel Indicator
Service Type | NC | NCI | SECNCI |
---|---|---|---|
STS1 IEF Loop (for subtending DS1 only) | JI-- | 04ST6.A | 04ST6.A |
OC3 STUB HUB | OBTD | 04SOF,B.D.F.X | 04CMF.C3 |
OC12 STUB HUB | ODTD | 04SOF,B.D.F.X | 04CMF.C12 |
OC48 MID SPAN MEET | OFTC | 04SOF,B.D.F.X | 04SSF.000 |
SUBTENDING SERVICES: *See note below | NC | NCI | SECNCI |
---|---|---|---|
DS3 | HF--/ HFC- | 04SOF,B.D.F.X 04DS6.44 04DS6.A 04SOF,B.D.F.X |
04DS6.44 04SOF,B.D.F.X |
MUXED DS3 | HF-M/HFZM | 04SOF,B.D. F.X | BLANK |
STS1 | JI-- | 04SOF,B.D. F.X 04ST6.A 04SOF,B.D. F.X | 04ST6.A 04SOF,B.D.F.X 04SOF,B.D.F.X |
STS1/DS3 | JI-- | 04SOF,B.D. F.X | 04ST6.A |
MUXED STS1 | JIAA | 04SOF,B.D. F.X 04ST6.A | BLANK |
IBT OC3/OC3C | OBT-/OBTR | 04SOF,B.D. F.X 02 or 04SOF,B.D. F.X | 02 or 04SOF,B.D.F.X 04SOF,B.D.F.X |
IBT OC12/OC12C | ODT-/ODTR | 04SOF,B.D. F.X 02 or 04SOF,B.D. F.X | 02 or 04SOF,B.D.F.X 04SOF,B.D.F.X |
IBT OC03 (basic, single CO mux) | OB-C | 04SOF.B D .F.X | 04SMF.A0C 04SMF.A18 04SMF.A24 04SMF.A3 |
IBT OC03 (w/ FPD, single CO mux) | OBTC | 04SOF.B D .F.X | 04SMF.A0C 04SMF.A18 04SMF.A24 04SMF.A3 |
IBT OC03 (basic, single premise mux) | OB-D | 04SOF.B D .F.X | 04SMF.A0C 04SMF.A18 04SMF.A24 04SMF.A3 |
IBT OC03 (w/ FPD, single premise mux) | OBTD | 04SOF.B D .F.X | 04SMF.A0C 04SMF.A18 04SMF.A24 04SMF.A3 |
IBT OC03 (basic, muxed at both ends [either premise/CO or premise/premise]) | OB-E | 04SMF.A0C 04SMF.A18 04SMF.A24 04SMF.A3 | 04SMF.A0C 04SMF.A18 04SMF.A24 04SMF.A3 |
IBT OC03 (w/ FPD, muxed at both ends [either premise/CO or premise/premise]) | OBTE | 04SMF.A0C 04SMF.A18 04SMF.A24 04SMF.A3 | 04SMF.A0C 04SMF.A18 04SMF.A24 04SMF.A3 |
IBT OC12 (basic, single CO mux) | OD-C | 04SOF.B D .F.X | 04SMF.AC 04SMF.B9 04SMF.C6 04SMF.D3 04SMF.E |
IBT OC12 (w/ FPD, single CO mux) | ODTC | 04SOF.B D .F.X | 04SMF.AC 04SMF.B9 04SMF.C6 04SMF.D3 04SMF.E |
IBT OC12 (basic, single premise mux) | OD-D | 04SOF.B D .F.X | 04SMF.AC 04SMF.B9 04SMF.C6 04SMF.D3 04SMF.E |
IBT OC12 (w/ FPD, single premise mux) | ODTD | 04SOF.B D .F.X | 04SMF.AC 04SMF.B9 04SMF.C6 04SMF.D3 04SMF.E |
IBT OC12 (basic, muxed at both ends [either premise/CO or premise/premise]) | OD-E | 04SMF.AC 04SMF.B9 04SMF.C6 04SMF.D3 04SMF.E | 04SMF.AC 04SMF.B9 04SMF.C6 04SMF.D3 04SMF.E |
IBT OC12 (w/ FPD, muxed at both ends [either premise/CO or premise/premise]) | ODTE | 04SMF.AC 04SMF.B9 04SMF.C6 04SMF.D3 04SMF.E | 04SMF.AC 04SMF.B9 04SMF.C6 04SMF.D3 04SMF.E |
*Subtending optical point-to-point (non-muxed) services: If there is an IEF interface at the Primary, Secondary or both locations, a four-fiber interface is required. Non-IEF interfaces can be two or four fiber. For OC3 Stub Hub, OC12 Stub Hub, or OC48 MSM, the NCI code needs to be optical (04SOF).
Service and Product Enhancement Code
Service and Product Enhancement Codes (SPEC) can be found in our SPEC Job Aid.
IEF Subtending Service SPEC Codes
Service Type | SPEC Entry | SPEC DESCRIPTION |
---|---|---|
Separated DS1, DS3 and STS1 | SALT2X | STS1 IEF BOTH ENDS |
Separated DS1, DS3 and STS1 | SALT3X | STS1 IEF AT PRILOC |
Separated DS1, DS3 and STS1 | SALT4X | STS1 IEF AT SECLOC |
Grouped DS1 | SALT2G | STS1 IEF BOTH ENDS |
Grouped DS1 | SALT3G | STS1 IEF AT PRILOC |
Grouped DS1 | SALT4G | STS1 IEF AT SECLOC |
Pt to Pt DS3 | SALTAX | IEF STUB HUB OR MID SPAN MEET AT PRILOC OR SECLOC |
Pt to Pt DS3 | SALTAA | IEF STS1 "like for like" AT PRILOC AND IEF STUB HUB OR MID SPAN MEET AT SECLOC |
Pt to Pt DS3 | SALTAB | IEF STS1 "like for like" AT SECLOC AND IEF STUB HUB OR MID SPAN MEET AT PRILOC |
Muxed DS3 | SALTBX | IEF STUB HUB OR MID SPAN MEET AT PRILOC |
Pt to Pt STS1 | SALTCX | IEF STUB HUB OR MID SPAN MEET AT PRILOC OR SECLOC |
Pt to Pt STS1 | SALTCA | IEF STS1 "like for like" AT PRILOC AND IEF STUB HUB OR MID SPAN MEET AT SECLOC |
Pt to Pt STS1 | SALTCB | IEF STS1 "like for like" AT SECLOC AND IEF STUB HUB OR MID SPAN MEET AT PRILOC |
Pt to Pt STS1/DS3 | SALTDX | IEF STUB HUB OR MID SPAN MEET AT PRILOC OR SECLOC |
Pt to Pt STS1/DS3 | SALTDA | IEF STS1 "like for like" AT PRILOC AND IEF STUB HUB OR MID SPAN MEET AT SECLOC |
Pt to Pt STS1/DS3 | SALTDB | IEF STS1 "like for like" AT SECLOC AND IEF STUB HUB OR MID SPAN MEET AT PRILOC |
Muxed STS1 | SALTEX | IEF STUB HUB OR MID SPAN MEET AT PRILOC OR SECLOC |
IBT OC3/OC3C | SALTFX | IEF STUB HUB OR MID SPAN MEET AT PRILOC OR SECLOC |
IBT OC3/OC3C | SALTFF | IEF STUB HUB OR MID SPAN MEET AT PRILOC AND SECLOC |
IBT OC3/OC3C | SALTYX | IEF STS3 "like for like" AT PRILOC AND NO IEF AT SECLOC |
IBT OC3/OC3C | SALTY2 | IEF STS3 "like for like" AT SECLOC AND NO IEF AT PRILOC |
IBT OC3/OC3C | SALTYY | IEF STS3 "like for like" AT PRILOC AND SECLOC |
IBT OC3/OC3C | SALTYF | IEF STS3 "like for like" AT PRILOC AND STUB HUB OR MID SPAN MEET AT SECLOC |
IBT OC3/OC3C | SALTFY | IEF STS3 "like for like" AT SECLOC AND STUB HUB OR MID SPAN MEET AT PRILOC |
IBT OC12/OC12C | SALTGX | IEF MID SPAN MEET AT PRILOC OR SECLOC |
IBT OC12/OC12C | SALTGG | MID SPAN MEET AT PRILOC AND SECLOC |
IBT OC12/OC12C | SALTZX | IEF STS12 "like for like" AT PRILOC AND NO IEF AT SECLOC |
IBT OC12/OC12C | SALTZ2 | IEF STS12 "like for like" AT SECLOC AND NO IEF AT PRILOC |
IBT OC12/OC12C | SALTZZ | IEF STS12 "like for like" AT PRILOC AND SECLOC |
IBT OC12/OC12C | SALTZG | IEF STS12 "like for like" AT PRILOC AND MID SPAN MEET AT SECLOC |
IBT OC12/OC12C | SALTGZ | IEF STS12 "like for like" AT SECLOC AND MID SPAN MEET AT PRILOC |
Variable Term Agreement
For additional information about the VTA field, please see the VTA Job Aid.