The Assembly Products are offered
pursuant to the NY PSC 8 Tariff, and provide for three
different arrangements:
- Assembly Room
- Assembly Point - Outside the Central Office - Wall
Mount
- Assembly Point - Outside the Central Office - Pad
Mount
The Assembly Products are provided as alternatives
to Physical and Virtual Collocation for the purposes
of facilitating a CLEC's ability to combine unbundled
loops and line ports.
The Assembly Room is located in a secured space within
a Verizon central office. Unbundled loops and line ports
are combined on a CLEC Common Termination Frame (CTF).
The environmental properties normally associated with
central office conditioned space are not furnished.
The CLEC may not install any transmission equipment
within the Assembly Room arrangement. The CLEC may utilize
portable test equipment for the purposes of testing
unbundled loop(s) and port(s), but may not store this
portable test equipment in the Assembly Room. Verizon
provides remote access to CLECs through its RETAS system
to enable CLECs to perform MLT testing and trouble isolation
on CLEC combined loops and ports.
The Assembly Room is subject to availability of space
and facilities in each central office as requested by
the CLEC on a first come, first served basis.
Assembly Points will be offered in lieu of the Assembly
Room in locations where:
- Space is limited
- Space cannot be secured
- The central office does not have 24 X 7 access without
callout
- Zoning and facility security conditions permit
The Assembly Points will not be offered at locations
in which Assembly Rooms are provided.
These Assembly Points are locked termination enclosures
outside central offices. The two types of outside enclosures
are:
- The Wall Mount Assembly Point, which consists of
a Termination Splice Box (TSB) which is a secure outdoor-rated
cabinet providing termination, access and cross-connect
flexibility. This box can be either wall - or post-mounted.
- The Terminal Pad Mounted Outside Plant Cabinet which
is equipped with connectorized cross-connect terminal
blocks. A double door access unit consisting of 2700
pair counts is provided. The blocks are enclosed in
a lightweight aluminum cabinet for easier handling.
These units provide termination, access and cross-connect
flexibility.
|
|
|
The Basic components of the rate
structure are as follows:
Application and Engineering Fees
Application Fee
To order services to the Assembly Room or Assembly Point, the
CLEC must fill out an Application and submit it, with an application
fee, to Verizon in accordance with terms and conditions of NY
PSC 8 Tariff.
Engineering and Implementation
Fee
This fee is applied upon completion of each request
for an Assembly Product. This fee applies in addition
to the Application fee.
Service Access Charge (SAC)
The SAC provides the physical connection between the
CLECs terminal blocks and the Verizon network. It consists
of terminal blocks located in the CLEC Common Termination
Frame or Assembly Point Cabinets and cabling and terminations
on Verizon frames. The SAC for voice grade and DS0 elements
terminate on a central office distributing frame (CODF).
SAC - CTF Termination (NRC)
These costs are based on the installed investment of
each terminal block that resides in the CTF. The non-recurring
rate element will be applied per (100) DS0/voice grade.
This non-recurring SAC charge applies at the time of
CLEC arrangement build.
SAC (Recurring)
There are two components that make up the recurring
SAC. The CTF termination portion and the cabling and
frame termination portion which consists of the cabling
necessary to connect the CTF to Verizon's frame
for the purpose of accessing VG/DS0 loops and ports.
Application of the SAC at the
Assembly Points
The cabinets for wall and pad mounted assembly points
come pre-installed with the appropriate DS0/VG terminal
blocks. The SAC NRC and recurring SAC CTF termination
rate are not applicable. The only SAC charge that would
apply in these instances would be the recurring charge
for SAC Cable and Frame terminations. This rate structure
mirrors the way the SAC is applied to POT Bay option
2 for physical collocation under the NY PSC 8 Tariff.
Assembly Room Charge
This monthly recurring charge assessed is on a per terminal
block basis.
Assembly Point Charge (Wall mounted)
This monthly recurring charge is applied on a per terminal
block basis.
Assembly Point Charge (Pad mounted)
This monthly recurring charge is applied on a per terminal
block basis.
|
|