Verizon Partner Solutions
\ Doing Business
\ Collocation
\ Arrangements
|
|
Competitive Fiber Providers (CATT)
|
|
|
|
Competitive Fiber
Providers |
|
|
|
|
|
Product
Description | Cable Installation
| Pricing Information |
|
|
|
|
|
This service allows competitive (3rd
party) fiber providers (CFPs) access to a shared alternate
splice point, hereafter referred to as the Competitive
Alternate Transport Terminal (CATT), in or near a Verizon
vault for the purposes of terminating CFP fiber facilities
for distribution to collocation arrangements within
a central office. This offering is filed in FCC No.
1 and FCC No. 11. The description of CATT set forth
below is based on such current tariff offerings and
is subject to change based on, among other things, modifications
to these tariffs. To the extent that there is a conflict
or inconsistency between the description in this Section
4.6. and such tariffs, the terms set forth in the tariff
shall prevail.
|
|
back to top |
|
|
|
Product
Description |
|
|
|
|
- The CFP must submit an application along with the
application fee for all CATT requests.
- The CFP must contract with a Verizon approved vendor
to install the CFP's fiber under escort.
- CFPs may pull a maximum of 432 fibers and a minimum
of 72 fibers per entrance manhole to be ultimately
spliced at the CATT.
- CFPs will be billed for the entire capacity of the
fiber pulled into the Verizon premises regardless
of how much of that fiber is spliced initially.
- CFPs will be required to splice and terminate a
minimum of 24 strands per fiber cable installation
for use within the central office.
- An additional 432 fibers maximum, 72 fibers minimum,
for a particular office may be pulled in via a separate
manhole for diversity where manhole space and conduit
is available. Where such diversity does not exist,
the CFP may request special construction options as
exist in applicable tariffs.
- The CATT will be located in or near the vault as
determined by Verizon.
- Verizon will provide equipment support (bay and
floor space) for the CATT. The CFP will provide splice
enclosures/trays.
- Splice enclosures installed must equate to the capacity
of the fiber installed at 72 fibers per shelf.
- CFP equipment must conform to NEBS standards as
defined in the collocation sections of the FCC tariffs.
- The CFP will be responsible for all splicing at
the CATT.
- Space for additional shelves for future use may
be reserved, if available, until such time as Verizon
requires the reserved shelves to meet another CFP's
request.
- The CFP shall not store any ancillary equipment
within the CATT area.
- Fiber will be distributed at a minimum of 12 strands
to collocation arrangements (virtual or physical).
Collocators will submit collocation applications to
request fiber to their collocation arrangements during
site implementation or augment and pay existing virtual
or physical collocation cable support and cable installation
charges in Verizon-South, and cable support per linear
foot to the physical arrangement or cabling to the
FDF per 12 strands in virtual collocation in Verizon-North.
- On all CATT installations, the CFP shall complete
Methods of Procedures (MOP) detailing the installation
work to be performed by the CFP. The MOP shall be
agreed upon and signed by a Verizon representative
and a CFP representative prior to the beginning of
any work effort within the CATT space. The CFP shall
prominently display the signed MOP at the equipment
bay while performing any work functions.
|
|
back to top |
|
|
|
Cable
Installation |
|
|
|
|
The CFP is allowed to place its cable
in the central office vault. The Verizon outside plant engineer
verifies an approved fire retardant riser cable. An authorized
Verizon representative accompanies the CFP or approved agent
completing the splicing at the CATT. A Verizon approved fire
retardant splice closure must be used. All bonding and grounding
procedures need to be followed.
If the CFP plans to fusion splice the transition point
of the outside plant fiber to the building rated fire
retardant fiber, an alternate splice area may be required.
Verizon provides and owns the equipment bay. The CFP
supplies a Verizon approved splice tray. A Verizon representative
conducts a quality inspection when the work is completed.
Attenuation, if required, is the responsibility of the
CFP. The fiber optic cable is CFP provided and owned
and all maintenance is the responsibility of the CFP.
See rate section following for a description of cable
installation from the CATT to collocation arrangements.
|
|
back to top |
|
|
|
Pricing
Information |
|
|
|
|
The basic components of the CATT
rate structure are as follows, although other charges
may apply:
The Application Fee
The Application Fee is submitted by the CFP with all
requests for the application processing and administrative
activities performed by the Wholesale Markets contact
and the initial engineering site survey.
If a CFP cancels any of the above requests prior to
installation, any unused portion of the application
fee will be refunded
Engineering and Implementation
Fee
This fee will apply to the CFP for all requests from
the CFP for planning, Verizon engineering and project
management of the CATT arrangement. This applies to
new arrangements, as well as to equipment additions
to existing arrangements.
Fiber Placement and Splice Charges
CATT to Collocation Arrangements
(Billed to Collocator - see also Specific Collocator
Rates Following)
CATT to Physical Collocation
Arrangement - NY
Under the existing procedures, the collocator is required
to place fiber (minimum 12 strands) from the CATT to
the collocator's physical collocation arrangement.
The collocator must use a Verizon approved vendor and
must conform to Verizon's engineering specifications.
Verizon incurs costs associated with the activities
performed by the Verizon outside plant technicians supervising
the collocator's installation activities. These
costs will be recovered on a time and materials basis
and are billed to the collocator.
CATT to Physical Collocation
Arrangement - NE
Under the existing procedures, hourly rates apply for
Verizon technicians/engineers to pull the fiber (minimum
12 strands) provided by the collocator from the CATT
to the physical collocation arrangement. The amount
of time required to pull the fiber will depend on the
collocator, the particular central office and the location
of the physical collocation arrangement. This cost will
be recovered on a time and materials basis and is billed
to the collocator.
CATT to Physical Collocation
Arrangement - Verizon- South
Under the existing collocation procedures, Verizon will
pull the fiber (minimum 12 strands) provided by the
collocator from the CATT to the physical collocation
arrangement. The CFP will be responsible for the splicing
at the CATT. Existing rates for cable installation and
support will apply.
CATT to Virtual Collocation Arrangement
- NY and NE
Verizon will provide and hand off fiber (per 12 strands)
from the virtual FDF to the CFP in the CATT area. The
CFP will do the splice at the CATT. The demarc between
the CFP and the collocator will be a minimum of five
feet from the CATT.
The collocator will order cross connects from the collocator's
virtual arrangements according to existing practices
in the collocation tariffs.
CATT to Virtual Collocation Arrangement - Verizon-South
Verizon will hand off collocator provided fiber from the virtually
collocated equipment to the CFP in the CATT area. The CFP will
do the splice at the CATT. The demarc between the CFP and the
collocator will be a minimum of five feet from the CATT. Existing
rates for cable installation and support will apply.
Manhole to CATT - Entire
Region (Billed to CFP)
Verizon incurs costs associated with the activities
performed by Verizon outside plant technicians supervising
the CFP's installation activities. The amount
of time required to pull and splice the fiber will depend
on the CFP, the particular central office and the location
of the CATT. These costs will be recovered based on
established escort hours as described below.
Additional CFP Rates
Escort Service for Cable Installation
Escorts are required for all activities performed from
the manhole to the CATT and from the CATT to a physical
collocation arrangement.
Non-recurring labor rates, per engineer/technician apply
per half-hour. The labor rates are currently tariffed
in FCC No. 11, Section 31.13.2 in Verizon-North, and
FCC No.1, Section 13 in Verizon-South.
Cable Space Per Cable
This fee applies to the CFP per cable installed for
the support between the manhole and the CATT.
Equipment Support
This rate applies to the CFP and is for monthly support
services including the cost of providing the equipment
bay for the splice enclosures and associated floor space.
The actual splice enclosures/trays will be provided
by the CFP. Equipment support will be billed per shelf/72
fibers.
Specific Collocator Rates
Cable Space Per Linear Foot Per
Cable - NY and NE
The existing rate in the FCC No. 11 applies to the collocator
for the support between the CATT and the physical collocation
arrangement.
CATT to Virtual FDF Per 12 Strands
- NY and NE
This new rate applies to the collocator and is associated
with providing and servicing the Optical Fiber Non-metallic
Riser-rated (OFNR) type fibers and associated FDF frame
termination. It is assessed in units of twelve strands
terminated.
Cable Installation - Verizon-South
The existing rates in FCC No. 1 apply to the collocator
for installation of cable by Verizon from a physical
or virtual collocation arrangement to the CATT area.
Cable Support - Verizon-South
The existing rates in FCC No. 1 apply to the collocator
for the support of the cable, via conduit or racking,
from the CATT to a physical or virtual collocation arrangement.
|
|
back to top |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|